First article inspection

First article inspection software, from drawing review to recorded results.

Prepare the drawing requirements, guide the inspector through each characteristic, and keep results connected to their source. QuickFAI helps manufacturing quality teams move from a ballooned PDF to measurement recording and FAI report preparation in the browser.

  1. 01

    Prepare the characteristics

    Confirm the drawing revision, review the extracted requirements, and connect each characteristic to its balloon number. Resolve ambiguous requirements before inspection begins.

  2. 02

    Capture the measurement

    Enter results against the active characteristic. Shop Floor Pro adds guided inspection and keyboard wedge input, where a compatible caliper sends its value as keyboard input.

  3. 03

    Review and export

    Check incomplete and out-of-tolerance results before preparing the report. Follow your approved process for reviewing discrepancies, attaching evidence, and releasing the inspection record.

Inside the application

Keep the requirement in view while measuring.

These captures come from the running product using a synthetic regression drawing. They show the actual interface with example values, including an out-of-tolerance measurement.

Actual application in guided measuring mode: balloon 1, diameter 12 plus or minus 0.05, with a sample measurement of 12.01 mm.
Actual application screenshot · synthetic test drawing and example measurements. Guided entry keeps the active requirement and measured value together.
Download the synthetic source drawing (PDF)

See the actual inspection report output.

These anonymized product exports show 30 characteristics in two result scenarios. The original drawing annex and source filename have been removed for public sharing. Measurement values are unchanged. These samples use a different drawing from the synthetic screenshots above and are not released inspection records.

Worked example · fictional part

Follow a measurement into the inspection report

For balloon 3, the accepted interval is 8.40–8.60 mm. A measured value of 8.65 mm falls outside that interval and needs review before release. This illustration explains the workflow; it is not a customer drawing or a product screenshot.

120.00 ±0.0575.00 ±0.05Ø8.50 ±0.10ILLUSTRATIVE PART · UNITS: mm · NOT TO SCALE123
Ballooned drawing: the identifier stays connected to its requirement.
BALLOON 03 · HOLE DIAMETER

8.65 mm

Out of tolerance · upper limit 8.60 mm

Retain the original result, check the measurement, and follow the disposition process required by your quality procedure.

Illustrative inspection rows · all dimensions in millimetres
BalloonCharacteristicRequirementMeasuredResult
1Overall length120.00 ±0.05120.02Pass
2Overall height75.00 ±0.0574.98Pass
3Hole diameter8.50 ±0.108.65Out of tolerance

An FAI report generator with drawing context

A report is useful when each result can be traced back to the requirement being checked. QuickFAI connects the characteristic list and measured values with the ballooned drawing. Use it to prepare inspection records while keeping the source requirement available to the reviewer.

Measurement entry at the inspection station

The guided workflow is intended for desktop and tablet inspection stations. Manual entry works without a connected gauge. Compatible keyboard wedge devices can send measurements into the active input; confirm device behavior, units, decimal formatting, and the receiving field before inspecting a complete part.

Make out-of-tolerance results visible

A value outside the accepted interval needs a review and disposition under your quality procedure. Keep the recorded value and its characteristic reference together. Do not replace an actual measurement with the nominal value to make a row pass. The sample inspection demonstrates a hole measurement above its upper limit.

Choose the report format your customer requires

Standard Excel and PDF inspection exports are listed in the Starter plan. AS9102 Forms 1, 2, and 3 and CMM import are listed in Enterprise Mid. Confirm the required forms, revision, supporting evidence, and customer-specific fields with us. A dimensional report alone does not establish that a complete FAI package meets every applicable requirement.

Questions about first article inspection

What does first article inspection software help with?

It helps organize drawing characteristics, capture measurements, and prepare inspection records. Your organization still defines the inspection scope, verifies the requirements, and approves the final package.

Can QuickFAI generate an FAI report?

QuickFAI lists standard Excel and PDF inspection report export in Starter and AS9102 forms in Enterprise Mid. Contact us with your actual report template to confirm the output you need.

Does using this software guarantee AS9102 compliance?

No. The applicable standard, customer requirements, inspection evidence, and your approval process determine whether a package is acceptable. Software supports that process and does not replace it.

Can I connect digital calipers?

Shop Floor Pro lists keyboard wedge caliper input. A compatible device must send the measurement as keyboard input. Confirm compatibility with your exact gauge and connection setup before deployment.